Characterization of Nanoparticles

 

Characterization of Nanoparticles

1. Meaning of Characterization

Characterization means studying the important properties/features of nanoparticles.

It helps us know:

  • Composition – nanoparticles mein kaunse elements/chemicals present hain.
  • Structure – atoms/molecules ka arrangement kaisa hai.
  • Size and shape – particle kitna small hai aur kis shape ka hai.
  • Physical properties
  • Electrical properties
  • Magnetic properties
  • Optical properties

Why is characterization important?

Nanoparticles ki properties unke size aur shape ke according significantly change ho sakti hain.

Therefore, accurate measurement of size, shape and structure is very important for their application.

 

2. General Characterization Methods

A. Microscopy

1.    Scanning Electron Microscopy (SEM)

2.    Transmission Electron Microscopy (TEM)

3.    Scanning Tunneling Microscopy (STM)

B. Spectroscopy

1.    X-ray Diffraction (XRD)

2.    Small Angle X-ray Scattering (SAXS)

3.    X-ray Photoelectron Spectroscopy (XPS)

4.    UV-Visible Spectroscopy

5.    FT-IR Spectroscopy

 

A. MICROSCOPY

Microscopy techniques are used to visualize nanoparticles and study their size, shape, morphology and structure.

 

1. Scanning Electron Microscopy — SEM

Principle

SEM uses a focused electron beam to scan the surface of a sample.

When the electron beam strikes the sample, different signals are produced, mainly:

  • Secondary electrons
  • Back-scattered electrons
  • Characteristic X-rays

These signals are detected and converted into an image.

Simple principle

Electron beam → strikes sample surface → electrons/signals produced → detector → image

SEM is mainly useful for studying the surface of nanoparticles.

What can we see with SEM?

1. Topography

It shows the texture/surface of the sample.

2. Morphology

It gives information about:

  • Size
  • Shape
  • Arrangement/order of particles

3. Composition

It can provide information about the elemental composition.

4. Crystalline structure

It can give information about the arrangement present within the sample.

 

SEM Instrument

An electron gun produces the electron beam.

The beam is focused using electromagnetic lenses and scanned across the sample surface.

The signals produced from the sample are detected and converted into an image.

The electron gun can operate approximately at 1–30 kV for SEM.

 

Magnification

SEM: approximately 10–500,000×

 

Advantages of SEM

1.    Bulk samples can be observed.

2.    A relatively large sample area can be viewed.

3.    Produces photo-like images.

4.    Produces high-resolution images.

5.    Provides useful information about sample purity and degree of aggregation.

 

Disadvantages of SEM

1.    Sample generally needs to have surface electrical conductivity.

2.    Non-conductive samples may need to be coated with a conductive layer.

3.    It can be time-consuming and expensive.

4.    Sometimes it is difficult to clearly differentiate nanoparticles from the substrate.

5.    SEM cannot resolve the internal structure of some domains.

 

2. Transmission Electron Microscopy — TEM

Principle

In TEM, a high-energy electron beam is transmitted through a very thin sample.

The electrons interact with the sample. Differences in electron transmission produce contrast and form an image.

Simple principle

Electron beam → thin sample → transmitted/scattered electrons → detector → image

TEM is particularly useful when very high resolution is required.

 

What can we see with TEM?

1. Morphology

It gives:

  • Shape
  • Size
  • Order/arrangement of nanoparticles

2. Crystalline structure

It can show:

  • Arrangement of atoms
  • Defects in crystalline structure

3. Composition

It can provide information about the elemental composition of the sample.

 

TEM Instrument

An electron gun produces the electron beam.

The beam is focused using electromagnetic lenses and transmitted through the specimen.

TEM generally operates at approximately 80–300 kV.

Magnification

TEM: approximately 2,000–1,000,000×

 

Advantages of TEM

1.    Very high resolution.

2.    High-resolution images are possible.

3.    Additional analysis such as X-ray spectrometry can be possible with TEM.

4.    Image construction can show internal/nanostructural information.

5.    Useful for studying interactions involving gases, liquids and biological structures when appropriate sample preparation is used.

 

Disadvantages of TEM

1.    Sample must withstand the electron beam.

2.    Sample must be sufficiently thin.

3.    Sample preparation is necessary.

4.    Mostly used for 2-D images.

5.    Preparation and analysis can be time-consuming.

 

SEM vs TEM

Feature

SEM

TEM

Main purpose

Surface/morphology

Internal structure + morphology

Sample

Bulk/surface sample

Very thin sample

Magnification

~10–500,000×

~2,000–1,000,000×

Depth resolution

10–1000 nm

1–10 nm

Lateral resolution

1–10 nm

0.1–1 nm

Image

Surface appearance

Transmitted electron image

Sample preparation

Comparatively easier

More demanding

Easy way to remember:

SEM = Surface

TEM = Through the sample

 

3. Scanning Tunneling Microscopy — STM

Principle

STM is based on the concept of quantum tunneling.

When a conducting tip is brought extremely close to a conducting or semi-conducting surface, a small voltage between the tip and surface allows electrons to tunnel between them.

The tunneling current changes according to the distance between the tip and surface.

These changes are converted into an image.

Simple principle

Sharp tip + very close surface + voltage → tunneling current → image

The technique can provide extremely high-resolution surface images.

 

Resolution

The PPT gives approximately:

  • Lateral resolution: ~0.1 nm
  • Depth resolution: ~0.01 nm

 

Advantages of STM

1.    Very high image resolution.

2.    Capable of observing/manipulating atoms.

3.    Can be used not only under ultra-high vacuum but also in air and various liquids.

4.    Can operate at ambient and elevated temperatures.

 

Disadvantages of STM

1.    Tip curvature can affect the result.

2.    Tip radius can introduce problems.

3.    Very sensitive to environmental vibrations.

4.    Requires extremely clean surfaces and sharp tips.

5.    Mainly suitable for conducting or semiconducting surfaces.

 

B. SPECTROSCOPY

Spectroscopy studies the interaction of radiation with matter to obtain information about nanoparticles.

The PPT includes:

1.    XRD

2.    SAXS

3.    XPS

4.    UV-Visible spectroscopy

5.    FT-IR spectroscopy

 

1. X-Ray Diffraction — XRD

Principle

XRD is based on the diffraction of X-rays by crystal planes.

When X-rays fall on a crystalline material, they are diffracted by the regularly arranged atoms.

The diffraction condition is described by Bragg's law:

nλ = 2d sin θ

Where:

  • n = order of diffraction
  • λ = wavelength of X-ray
  • d = distance between crystal planes
  • θ = Bragg angle

 

What does XRD characterize?

XRD can provide information about:

1.    Lattice constant

2.    d-spacing

3.    Crystal structure

4.    Crystallite size

5.    Sample orientation

6.    Particle size/grain size

 

Crystallite size

The PPT gives the Scherrer equation:

t = Kλ / B cosθ

Where:

  • t = thickness/crystallite size
  • K = shape constant
  • λ = wavelength
  • B = FWHM
  • θ = Bragg angle

Important point

Smaller crystals → broader XRD peaks

XRD can be time-consuming and may require a relatively large amount of sample.

 

2. Small Angle X-Ray Scattering — SAXS

Principle

SAXS studies X-ray scattering produced by inhomogeneities/structures at the nanometer scale.

It is useful for studying structures from several nanometers to larger nanoscale dimensions.

 

What can SAXS characterize?

1.    Particle size

2.    Specific surface area

3.    Morphology

4.    Porosity

It can provide structural information over length scales approximately from nanometers to larger dimensions, as described in the PPT.

Important point

SAXS is useful for studying partially ordered systems and nanoscale structures.

 

3. X-Ray Photoelectron Spectroscopy — XPS

XPS is a surface-sensitive characterization technique.

It provides information about the elemental composition and chemical state of the surface.

 

Principle

X-rays strike the sample surface.

The X-rays cause emission of photoelectrons.

The energy of the emitted electrons is measured.

From this, information about the elements and their chemical states can be obtained.

Simple flow

X-ray → sample → photoelectron emitted → kinetic/binding energy measured → elemental & chemical information

 

What is XPS used for?

XPS can determine:

  • What elements are present on the surface
  • Quantity of elements
  • Surface contamination
  • Empirical formula
  • Chemical state of elements
  • Binding energy of electronic states
  • Thickness of different materials
  • Density of electronic states

XPS is generally sensitive to the near-surface region, approximately 1–12 nm as stated in the PPT.

 

Materials analyzed by XPS

XPS can be used for:

  • Inorganic compounds
  • Metals
  • Semiconductors
  • Polymers
  • Ceramics
  • Other suitable materials

The PPT notes that organic chemicals are not routinely analyzed because they may be degraded by X-ray energy or heat from non-monochromatic X-ray sources.

 

Important limitation

XPS detects elements with atomic number > 2 according to the PPT.

It cannot normally detect hydrogen (Z = 1) and helium (Z = 2) because of their very small orbital diameter and extremely low detection probability.

 

4. UV-Visible Spectroscopy

Principle

UV-Visible spectroscopy involves the absorption of near-UV or visible light by a material.

It measures:

  • Intensity
  • Wavelength

It is commonly applied to molecules and inorganic ions in solution.

 

Beer-Lambert Law

The PPT gives:

A = −log(I/I₀) = a × b × c

Where:

  • A = absorbance
  • I = intensity of transmitted light
  • I₀ = incident light intensity
  • a = absorptivity
  • b = path length
  • c = concentration

Application

It can be used to determine the concentration of an analyte from its absorbance.

For nanoparticles, UV-Vis spectroscopy can also help study their optical properties.

 

5. FT-IR Spectroscopy

FT-IR = Fourier Transform Infrared Spectroscopy

Principle

Molecules can be considered as systems of atoms connected by bonds.

These bonds can vibrate.

When infrared radiation interacts with the sample, it can be absorbed when its frequency matches the vibrational frequency of a bond.

Therefore, FT-IR provides information about the chemical bonds and functional groups present in the sample.

Simple flow

IR radiation → sample → molecular vibration → IR absorption → spectrum → functional-group information

 

What can FT-IR characterize?

The PPT lists:

1.    Composition

2.    Concentration

3.    Atomic structure

4.    Surrounding environment/atomic arrangement

It is particularly useful for studying the chemical environment and molecular/crystal vibrations.

 

Quick Revision Table

Technique

Main information obtained

SEM

Surface morphology, size, shape, topography

TEM

Internal structure, morphology, crystal defects, high-resolution images

STM

Atomic/surface structure, extremely high resolution

XRD

Crystal structure, d-spacing, crystallite size

SAXS

Nanoparticle size, surface area, morphology, porosity

XPS

Surface elements, chemical state, binding energy

UV-Vis

Absorption, optical properties, concentration

FT-IR

Functional groups, chemical bonds, molecular vibrations

One-line memory trick

Microscopy → “How does the particle look?”

XRD → “How are atoms arranged in the crystal?”

SAXS → “What is the nanoscale structure/size?”

XPS → “Which elements and chemical states are on the surface?”

UV-Vis → “How does it absorb UV/visible light?”

FT-IR → “Which bonds/functional groups are present?”

This is the rewrite based on the uploaded PPT's own classification and content—not a new classification.

Top of Form

Bottom of Form

 


Post a Comment

Previous Post Next Post